Free Shipping For All Orders

CPAP Cleaner and Sanitizing Machine with UV & Ozone Dual Mode

Original price was: $259.99.Current price is: $169.99.

Ready to Ship, US warehouse: USPS delivery time 2-6 working days.

Availability: In stock

Satisfaction Guarantee

Fast Shipping

Free Returns

The Sinoriko UO-X1 is a CPAP cleaner with ozone and UV-C dual disinfection.
It kills 99.9% of germs such as Escherichia coli and Staphylococcus aureus.

  • UV-C light directly irradiates the surface of the CPAP accessories, effectively disrupting the DNA structure of microorganisms and rapidly eliminating pathogens exposed to the light.
  • Ozone gas can penetrate hard-to-reach areas within the CPAP equipment, such as the interior of tubing and the crevices of masks, eradicating hidden bacteria and odors.

This product not only cleans your CPAP accessories, but can also be used as a multi-purpose disinfection device for other personal care products. (i.e. electric toothbrush, toys, cell phones, etc).

ModelUO-X1
Item dimensions7.96 x 11.1 x 7.96 inch
Weight3.6 lbs
Working TechnologyUV + Ozone Mode
UV LED Power3W
Adaptor InputAC 100~240V, 50/60HZ
Adaptor outputDC 12V, 2.5A Max
Operating Temperature50°F to 100°F (10°C to 38°C)
Operating Humidity15% to 75%
Area of intended useIndoor
Sound LevelAbout 30 dB
RegionETACourier
USA3 – 9 working daysUSPS
Clean Icon

Quick 5-minute CPAP sanitizing

Bacteria Icon

Effectively kills 99.9% of bacteria

Locked Icon

Safe and easy to use

Ecology Icon

No Harmful Chemicals/Gasses

Product Page-Timer Icon

4-Level Timer

UV mode: 5/10/15/20 mins
Ozone mode: 45/55/65/75 mins

Product Page-Multi Use Icon

Multi-use Design

All CPAP device and accessories are available

Product Page-UV&Ozone Dual Mode Icon

UV & Ozone Dual Mode

Single or double mode selection available

Product Page-Wide Compatibility Icon

Wide Compatibility

Equipped with a hose sleeve compatible with almost CPAP machines

Product Page-Clean Germ&Bacteria Icon

Exceptionally Effective Sterilization

Cleans 99.9% of germs & bacteria

Product Page-Anti Accidental Icon

Anti-accidental Opening Design

Automatically shuts down if the lid is accidentally opened

How Sinoriko CPAP Cleaner Work?

Ozone Mode
(All-round Sterilization)

Sinoriko CPAP Cleaning Machine Ozone Mode

Ozone can penetrate deep into the CPAP machine and tubes, completely removing bacteria and viruses through circulation, and ensuring that every area is fully disinfected. Leveraging best-in-class engineering and cutting-edge technology, Sinoriko CPAP cleaner reduces bacteria by 99.9% on CPAP hoses and masks.

UV Mode
(Quick Sterilization)

Sinoriko CPAP Cleaning Machine UV Light Mode

UV-C light shines on a surface effectively destroying the DNA structure of microorganisms and killing pathogens exposed to the light within minutes. Sinoriko CPAP cleaner hospital-grade UV-C LEDs have a service life of 10,000 hours and do not need to be replaced.

Schematic diagram of ultraviolet wavelength

Quick 5 Min UV CPAP Sanitizer

The Sinoriko CPAP cleaning machine utilizes high-energy light within a narrow spectrum known as UVC light to ensure effective sanitization. It features a low-pressure, mercury-arc germicidal lamp engineered to generate maximum UVC output, with 90% of the energy concentrated around 254nm. This wavelength closely aligns with the germicidal effectiveness peak of 265nm, the most lethal wavelength for microorganisms. In just a 5-minute cycle, the emitted UVC light delivers a sufficient dose to eliminate most bacteria and mold on surfaces, ensuring thorough cleaning.

The Sinoriko CPAP cleaning machine’s UV mode offers four selectable durations: 5, 10, 15, and 20 minutes. You can adjust the sterilization time based on your specific needs to ensure thorough cleaning of masks or tubes.

Ozone Stream Technology CPAP Sanitizer

The Sinoriko CPAP cleaning machine’s ozone mode is designed for precise and effective sterilization. When activated, the ozone stream travels seamlessly through your CPAP hose and mask, reaching even the most difficult-to-access areas. This powerful ozone technology works by breaking down harmful microorganisms, effectively reducing bacteria by up to 99.9%. The ozone’s strong oxidative properties ensure a deep and thorough cleanse, providing you with a higher level of sanitation and peace of mind, knowing that your CPAP equipment is free from bacteria, mold, and other harmful contaminants.

The Sinoriko CPAP cleaning machine’s ozone mode offers four selectable durations: 45, 55, 65, and 75 minutes. The ozone cycle begins with a 10-minute active ozone emission, followed by a stationary phase lasting 20, 30, 40, or 50 minutes. This stationary phase allows for the gradual dissipation of ozone, ensuring it is safely converted and expelled from the chamber to prevent any potential adverse effects from residual ozone. Afterward, a 15-minute fresh air cycle completes the process, ensuring that your CPAP equipment is properly ventilated and safe to use. You can adjust the sterilization time according to your specific needs, ensuring a thorough and effective cleaning of masks and tubes.

Sinoriko CPAP Cleaning Machine Ozone Mode Sterilization Diagram

99.9% Sterilization Rate

Disinfection Kills Escherichia Coli

Disinfection kills 99.9% of Escherichia coli

Disinfection Kills Staphylococcus

Disinfection kills 99.9% of Staphylococcus

Disinfection Kills Candida Albicans

Disinfection kills 99.9% of Candida albicans

Sinoriko safer and more efficient CPAP cleaner

No Harmful Chemicals and Gases

The Sinoriko CPAP cleaning machine uses UVC light, an environmentally friendly technology that leaves no harmful residues, toxic gases, or chemicals behind. UVC light systems are already being used to sanitize ambulances, emergency service vehicles, and other high-contact areas due to their effectiveness. When used appropriately, ozone further enhances the cleaning process, effectively eliminating germs in hard-to-reach places that are difficult to sanitize.

Sinoriko CPAP Cleaning Machine Large Capacity

Large Capacity

The Sinoriko CPAP cleaning machine features a spacious design with a large capacity, allowing it to accommodate not only masks and tubes but also other CPAP accessories. This offers greater flexibility and more options for effectively disinfecting your CPAP equipment.

Mom and Daughter Use Sinoriko CPAP Cleaning Machine

Safe & Easy to Use

The 5-20 minute UV cleaning cycle requires no water or harmful chemicals, making the Sinoriko CPAP sanitizer a safe and convenient choice for cleaning CPAP masks and accessories. Simply set the desired time for the ozone disinfection cycle, and the intelligent system will take care of the entire process, ensuring a thorough and hassle-free cleaning experience.

Sinoriko CPAP Cleaner Smart Operation Panel

Smart Touch Control Panel

  • Digital Display: The display shows a countdown.
  • Power Button: Long press 2 seconds to turn on or off.Short press to start/pause.
  • Timer Button: After the timer ends, you will hear a beep, and the machine will automatically shut down.
  • Ozone Button: Select the ozone button and then press power to start working. Or select the ozone and UV buttons at the same time.
  • UV Button: Select the UV button and then press power to start working. Or select the ozone and UV buttons at the same time.

Ozone Sterilization Mode

The ozone sterilization mode offers four time settings: 45, 55, 65, and 75 minutes.

UV Sterilization Mode

The UV sterilization mode offers four time settings: 5, 10, 15, and 20 minutes.

Dual Sterilization Mode

The dual sterilization mode offers four time settings: 45, 55, 65, and 75 minutes.

Replaceable Cleaner Filters & Check Valves

The replaceable filters and check valves of the Sinoriko CPAP cleaning machine are designed to significantly reduce your long-term usage costs while ensuring optimal performance. By regularly replacing these components, you can maintain the highest level of cleanliness and efficiency, guaranteeing a consistently superior CPAP experience at home. This cost-effective approach not only extends the lifespan of your device but also helps sustain the highest standards of hygiene, providing you with peace of mind and uninterrupted service.

Sinoriko CPAP cleaning machine package list

Two Ways Sterilize CPAP Machine

Sterilize the CPAP by connecting to the Sinoriko cleaning machine

Sterilize by connecting to the CPAP cleaning machine

Sterilize the CPAP mask and tube in the Sinoriko cleaning machine

Sterilize mask and tube in the CPAP cleaning machine

Sinoriko CPAP UV & Ozone Dual Mode Cleaning Machine Package

What's In The Box?

✅ 1* Sinoriko CPAP Cleaning Machine

✅ 1* Power Cord

✅ 1* Ozone Tube

✅ 1* 3-port Connector

✅ 1* 2-port Connector

✅ 1* Hose Sleeve

✅ 1* User Guide Manual

[cusrev_all_reviews]

Frequently Asked Questions

Moisture left in your mask or humidifier becomes a breeding ground for bacteria, germs and mold. Keeping your CPAP mask and humidifier free of harmful germs and bacteria helps avoid getting sick from a dirty CPAP.

No. The SINORIKO disinfects with activated oxygen and UV-C light. No fluids or water are
used in this process.

No. Ozone is also called active oxygen. The same sanitizing technology is safely used on
produce and drinking water. SINORIKO generates active oxygen in a closed system.

The active oxygen disinfects your equipment. During the last 15 minutes of the maintenance
cycle, the air pump inputs fresh air into SINORIKO. The active oxygen in the machine passes
through the filter and is converted back into ordinary oxygen before being released.

During the disinfection process, the timer button will keep flashing. When the disinfection is
complete, the machine will make a beeping sound and automatically shut down. This means
that the disinfection process has ended.

UV mode disinfects by emitting a narrow spectrum of high-energy light, known as UV-C. It is
designed to produce the highest amount of UV energy – 90% of which is produced at around
254nm. This light is very close to the peak of the germicidal effect curve at 265nm, which is the
most lethal wave to microorganisms. The dose of UV-C emitted in just a few minutes is enough to kill most bacteria and mold on a surface.

Because UV-C disinfection involves light waves, it operates in “line of sight” fashion, only
irradiating surfaces within its sightlines. If there is heightened need for disinfection, the mask
can be disassembled or a second cycle used after flipping the object over. For general daily
use, only one cycle is necessary.

  1. Before wearing your mask at bedtime, run your CPAP for 30 seconds to allow any residual scent to blow out.
  2. Try to disinfect your CPAP equipment early in the day to allow any lingering odors to dissipate before evening.
Scroll to Top